A+ A A-

Control (power) cable

oil-resistant multi-use like temperature measurement for hot-runner control systems

beispielbild

Article-No.ZonesIdentifierOuter
Sheath
M. Ø
ca. mm
2Z9305S 2 5 G 1,5 qmm PVC 6,7 mm
2Z9405S 2 5 G 2,5 qmm PVC 8,1 mm
3Z9307S 3 7 G 1,5 qmm PVC 8,9 mm
3Z9407S 3 7 G 2,5 qmm PVC 11,1 mm
4Z9309S 4 9 G 1,5 qmm PVC 11,4 mm
4Z9310S 4 10 G 1,5 qmm PVC 11,6 mm
6Z9314S 6 14 G 1,5 qmm PVC 12,7 mm
6Z9414S 6 14 G 2,5 qmm PVC 15,8 mm
8Z9318S 8 18 G 1,5 qmm PVC 14,4 mm
8Z9418S 8 18 G 2,5 qmm PVC 17,8 mm
12Z9325S 12 25 G 1,5 qmm PVC 16,9 mm
12Z9425S 12 25 G 2,5 qmm PVC 20,8 mm
16Z9134S 16 34 G 0,75 qmm PVC 15,9 mm
16Z9334S 16 34 G 1,5 qmm PVC 19,4 mm
16Z9434S 16 34 G 2,5 qmm PVC 24,4 mm
24Z9150S 24 50 G 0,75 qmm PVC 19,9 mm
24Z9350S 24 50 G 1,5 qmm PVC 23,5 mm
24Z9450S 24 50 G 2,5 qmm PVC 29,4 mm
32Z9065S 32 65 G 0,5 qmm PVC 19,6 mm
32Z9165S 32 65 G 0,75 qmm PVC 21,8 mm
36Z9080S 36 80 G 0,5 qmm PVC 21,1 mm
36Z9180S 36 80 G 0,75 qmm PVC 23,6 mm

No minimum quantities

Earth conductor: G = with earth conductor

Application range
Fixed laying as well as infrequent flexible use without tensile load in free, not repeatedly occurring movement. Dry or damp rooms with average mechanical strain.
Applicable for connection between hot runner and control device. Mantle material PVC, grey (RAL 7001)
Temperature range: infrequently moved: -15°C up to +70°C
In power track trains: -5°C up to +70°C
Fixed laying: -40°C up to +80°C
Cables are suitable for flexible use and fixed laying in dry and damp rooms with average mechanical strain. May not be used outdoor without UV-protection and only in consideration of the min./max. temperature range.
Norm-references / approvals VDE Reg.-Nr. 7030 for following dimensions:
up to 2,5 mm²: 2 - 65 leads, from 4 mm²: 2 - 7 leads, from 25 mm²: 2 - 5 leads

Product properties:
Flame-retardant compliant to IEC 60332-1-2
Good chemical durability, see catalogue annex T1
oil resistant compliant to DIN EN 50290-2-22 (TM54)
The fotos are not to scale and not detailed pictures of the specific products
Technical Data
Lead-Ident-Code: Black with white numbers compliant to VDE 0293-1
Classification: ETIM 5.0 Class-ID: EC000104
ETIM 5.0 Class-Description: control line
Isolation spezific
contact resistance:
> 20 GOhm x cm
Wire dress: finde-wired compliant to DIN EN 60228 (VDE 0295), Class 5 / IEC
60228 class 5
Torsion application in WKA: TW-0 & TW-1, see annex T0
Minimum bending range: infrequently moved: 10 x outer diameter
In power track train: 15 x outer diameter
Fixed laying: 4 x outer diameter
Nominal voltage: U₀/U: 300/500 V
Proof voltage: 4000 V